Product Details:
Place of Origin: China
Brand Name: Xi'an Shendian
Certification: Q/GDW 415-2010
Model Number: RXQ(D)-6~10
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc.
Price: To be determined by type and quantity.
Packaging Details: Seaworthy package/ Customer specified.
Delivery Time: Ex-work 1 week~1 month depends on quantity.
Payment Terms: T/T; L/C.
Supply Ability: 0.5M pc/year.

Voltage Sensitive Harmonic Elimination Device For Semi Insulation IT

Description
Nominal System Voltage: 6~10kV/ Customer Specified Usage: Voltage-sensitive
High Light:

6kV Harmonic Elimination Device

,

Voltage Sensitive Harmonic Elimination Device

,

6kV Voltage Sensitive Harmonic Eliminator

6-10kV Voltage-Sensitive Harmonic Eliminator Device For Semi-insulation IT
 
Product introduction:

Harmonic eliminator is used to eliminate the ferromagnetic resonance caused by grid operation, operation switching and ground fault, to limit the grounding current, and to protect the insulator of the potential transformer from damage. 

 
 
Characteristic:
1/ Big thermal capacity;
2/ Easy installation;
3/ Voltage-Sensitive;
4/ For semi-insulation instrument transformer.
 
 
Standard Technical Data:
Below info. only for your reference, all data shall be specified and determined by technical specification and customer demand.
 
ItemDescription Offered
1Manufacture/ Country of Origin Xi'an Shendian/ China
2Model RXQ(D)-6~10
3Nominal system voltagekV6~10
4Voltage at AC 1mAkV280~350
5Voltage at AC 10mAkV800~1000
6DC voltagekV1450~1650
7DC currentmA15
7Termination power frequency voltage limit of eliminator At 5kV, resistance shall be 50%.
8Nonlinear coefficient α 0.4~0.45
9Thermal capacity test
10min at power frequecny current 200mA;
2h at power frequecny current 200mA
 No visual damage.
U1mA and U10mA change before and after test ≤10%.
10Heightmm165

 
Schematic diagram: