Product Details:
|
Material: | Metal-oxide | Type: | Separable And Deadfront |
---|---|---|---|
Usage: | C-GIS Switchgear/ Gas Insulated RMU/ Oil Transformer | Nominal System Voltage: | 6kV~110kV/ Customer Specified |
Nominal Discharge Current: | 5kA/ 10kA | Diameter: | Φ68mm~ Φ138mm |
Height: | 309mm~ 845mm | Shape: | Straight/ Elbow |
High Light: | Straight Lightning Surge Arresters,10kA Lightning Surge Arresters,11kv 10ka lightning arrester |
Plug in separable and deadfront Surge Arrester
Product introduction:
Item | Description | Offered | Offered | Offered | Offered | |
1 | Manufacture/ Country of Origin | Xi'an Shendian/ China | ||||
2 | Model | CM-6 | CM-10 | CM-20 | CM-27.5 | |
3 | Applicable standard | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | |
4 | Type | Outdoor, ZnO, gapless | ||||
5 | Norminal voltage of system | kV | 6 | 10 | 20 | 27.5 |
6 | Earthing system | Effectively earthed | ||||
7 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 |
8 | Rated voltage of SA | kV | 10 | 17 | 26 | 42 |
9 | Maximum continuous operating voltage | kV | 8 | 13.6 | 20.8 | 34 |
10 | Power frequency reference voltage | kV | 14.4 | 24 | 37 | 65 |
11 | - at reference current of Note: State peak value or rms. |
mA (D.C) | 1 | 1 | 1 | 1 |
12 | Nominal discharge current | kA | 5 | 5 | 5 | 5 |
13 | (c) Lightning impulse | kV | ≤27 | ≤45 | ≤66 | ≤120 |
(d) Switching impulse | kV | ≤23 | ≤38.3 | ≤56 | ≤98 | |
14 | Inner cone | 2# | 2# | 2#/ 3# | 2#/ 3# | |
15 | Material of shell | Aluminium alloy | Aluminium alloy | Aluminium alloy | Aluminium alloy | |
16 | Diameter | mm | 68 | 68 | 96 | 138 |
17 | Height | mm | 309 | 309 | 350/375 | 590 |
Item | Description | Offered | Offered | Offered | Offered | Offered | |
1 | Manufacture/ Country of Origin | Xi'an Shendian/ China | |||||
2 | Model | CM-33 | CM-35 | CMZ-35 | CM-66 | CM-110 | |
3 | Applicable standard | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | |
4 | Type | Outdoor, ZnO, gapless | |||||
5 | Norminal voltage of system | kV | 33 | 35 | 35 | 66 | 110 |
6 | Earthing system | Effectively earthed | |||||
7 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
8 | Rated voltage of SA | kV | 51 | 51 | 51 | 90 | 108 |
9 | Maximum continuous operating voltage | kV | 40.8 | 40.8 | 40.8 | 72.5 | 84 |
10 | Power frequency reference voltage | kV | 70 | 73 | 73 | 130 | 157 |
11 | - at reference current of Note: State peak value or rms. |
mA (D.C) | 1 | 1 | 1 | 1 | 1 |
12 | Nominal discharge current | kA | 5 | 5 | 5 | 5 | 10 |
13 | (c) Lightning impulse | kV | ≤121 | ≤134 | ≤134 | ≤235 | ≤281 |
(d) Switching impulse | kV | ≤102 | ≤114 | ≤114 | ≤201 | ≤239 | |
14 | Inner cone | 2#/ 3# | 2#/ 3# | 2# | 4# | 4# | |
15 | Material of shell | Aluminium alloy | Aluminium alloy | Aluminium alloy | Aluminium alloy | Aluminium alloy | |
16 | Diameter | mm | 119 | 96 | 96 | 138 | 138 |
17 | Height | mm | 465/555 | 450/475 | 485 | 795 | 845 |