Product Details:
|
Material: | Metal-oxide | Type: | Gapless |
---|---|---|---|
Usage: | Indoor/ Outdoor | Color: | Red/ Grey/ Customer Specified |
Nominal System Voltage: | 3kV~ 110kV | Nominal Discharge Current: | 5kA/ 10kA |
Bushing Shed Dimension: | Φ88mm~ Φ377mm | Height: | 200mm~ 2200mm |
High Light: | 110kV Shunt Compensating Polymer Housed Surge Arrester,Shunt Compensating Polymer Housed Surge Arrester,Shunt Compensating Polymer Housed Surge Arrester Shendian |
Shunt Compensating Polymer Gapless Surge Arrester
Product introduction:
Item | Description | Offered | Offered | Offered | Offered | Offered | |
1 | Manufacture/ Country of Origin | Xi'an Shendian/ China | |||||
2 | Model | YH5WR-5/13.5 | YH5WR-10/27 | YH5WR-12/32.4 | YH5WR-15/40.5 | YH5WR-17/46 | |
3 | Applicable standard | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | |
4 | Type | Outdoor, ZnO, gapless | |||||
5 | Norminal voltage of system | kV | 3 | 6 | 10 | 10 | 10 |
6 | Earthing system | Effectively earthed | |||||
7 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
8 | Rated voltage of SA | kV | 5 | 10 | 12 | 15 | 17 |
9 | Maximum continuous operating voltage | kV | 4 | 8 | 9.6 | 12 | 13.6 |
10 | Power frequency reference voltage | kV | 7.2 | 14.4 | 17.4 | 21.8 | 24 |
11 | - at reference current of Note: State peak value or rms. |
mA (D.C) |
1 | 1 | 1 | 1 | 1 |
12 | Nominal discharge current | kA | 5 | 5 | 5 | 5 | 5 |
13 | (a) Lightning impulse | kV | ≤13.5 | ≤27 | ≤32.4 | ≤40.5 | ≤46 |
(b) Switching impulse | kV | ≤10.5 | ≤21 | ≤25.2 | ≤31.5 | ≤35 | |
14 | Material employed in series non-linear resistor | ZnO etc. | ZnO etc. | ZnO etc. | ZnO etc. | ZnO etc. | |
15 | Arrester housing: | ||||||
- Material | Polymer | Polymer | Polymer | Polymer | Polymer | ||
- Minimum creepage distance | mm/kV | 25/31 | 25/31 | 25/31 | 25/31 | 25/31 | |
16 | - HV terminal | hot zip screw | hot zip screw | hot zip screw | hot zip screw | hot zip screw | |
- earth terminal | hot zip screw | hot zip screw | hot zip screw | hot zip screw | hot zip screw | ||
17 | Diameter of bushing sheds | mm | 88 | 88 | 88 | 88 | 88 |
18 | Height | mm | 200 | 200 | 255 | 255 | 255 |
B: Nominal system voltage ≤35kV
Item | Description | Offered | Offered | Offered | |
1 | Manufacture/ Country of Origin | Xi'an Shendian/ China | |||
2 | Model | YH5WR-26/66 | YH5WR-32/85 | YH5WR-51/134 | |
3 | Applicable standard | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | |
4 | Type | Outdoor, ZnO, gapless | |||
5 | Norminal voltage of system | kV | 20 | 20 | 35 |
6 | Earthing system | Effectively earthed | |||
7 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 |
8 | Rated voltage of SA | kV | 26 | 32 | 51 |
9 | Maximum continuous operating voltage | kV | 20.8 | 25.6 | 40.8 |
10 | Power frequency reference voltage | kV | 37 | 47 | 73 |
11 | - at reference current of Note: State peak value or rms. |
mA (D.C) | 1 | 1 | 1 |
12 | Nominal discharge current | kA | 5 | 5 | 5 |
13 | (a) Lightning impulse | kV | ≤66 | ≤85 | ≤134 |
(b) Switching impulse | kV | ≤53 | ≤68 | ≤105 | |
14 | Material employed in series non-linear resistor | ZnO etc. | ZnO etc. | ZnO etc. | |
15 | Arrester housing: | ||||
- Material | Polymer | Polymer | Polymer | ||
- Minimum creepage distance | mm/kV | 25/31 | 25/31 | 25/31 | |
16 | - HV terminal | hot zip screw | hot zip screw | hot zip screw | |
- earth terminal | hot zip screw | hot zip screw | hot zip screw | ||
17 | Diameter of bushing sheds | mm | 120 | 120 | 120 |
18 | Height | mm | 345 | 405 | 525 |
Schematic diagram:
C: Nominal system voltage ≤110kV
Item | Description | Offered | Offered | Offered | Offered | Offered | |
1 | Manufacture/ Country of Origin | Xi'an Shendian/ China | |||||
2 | Model | YH5WR-84/221 | YH5WR-90/236 | YH10WR-105/265 | YH10WR-108/281 | YH10WR-174/372 | |
3 | Applicable standard | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | IEC 60099-4 | |
4 | Type | Outdoor, ZnO, gapless | |||||
5 | Norminal voltage of system | kV | 66 | 66 | 66 | 110 | 110 |
6 | Earthing system | Effectively earthed | |||||
7 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
8 | Rated voltage of SA | kV | 84 | 90 | 105 | 108 | 174 |
9 | Maximum continuous operating voltage | kV | 67.2 | 72.5 | 84 | 84 | 139 |
10 | Power frequency reference voltage | kV | 121 | 130 | 152 | 157 | 240 |
11 | - at reference current of Note: State peak value or rms. |
mA (D.C) |
1 | 1 | 1 | 1 | 1 |
12 | Nominal discharge current | kA | 5 | 5 | 10 | 10 | 10 |
13 | (a) Lightning impulse | kV | ≤221 | ≤236 | ≤265 | ≤281 | ≤372 |
(b) Switching impulse | kV | ≤176 | ≤190 | ≤225 | ≤239 | ≤336 | |
14 | Material employed in series non-linear resistor | ZnO etc. | ZnO etc. | ZnO etc. | ZnO etc. | ZnO etc. | |
15 | Arrester housing: | ||||||
- Material | Polymer | Polymer | Polymer | Polymer | Polymer | ||
- Minimum creepage distance | mm/kV | 25/31 | 25/31 | 25/31 | 25/31 | 25/31 | |
16 | - HV terminal | hot zip screw | hot zip screw | hot zip screw | hot zip screw | hot zip screw | |
- earth terminal | hot zip screw | hot zip screw | hot zip screw | hot zip screw | hot zip screw | ||
17 | Diameter of bushing sheds | mm | 195 | 195 | 195 | 195 | 377 |
18 | Height | mm | 1296 | 1296 | 1296 | 1296 | 2200 |
Schematic diagram:
Contact Person: Mr. xue feng
Tel: +86 13709223751